Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1992 Oxford University Press

article-commentary

Recommendations for the Conduct of Acute Inhalation Limit Tests

Prepared by the Technical Committee of the Inhalation Specialty Section, Society of Toxicology

Received October 18, 1991; accepted October 18, 1991

This paper reviews the scientific issues related to exposure concentrations and particle sizes used in acute inhalation limit tests. The current United States Environmental Protection Agency (USEPA) recommended exposure concentration for such tests is 5 mg/liter, while this level is very high, it is often achievable. On the other hand, its toxicological relevance is questionable. The USEPA recommendation that 25% of the particle distribution be less than 1 µm is a more difficult issue to address. Physical laws for aerosol particle generation and behavior limit the minimum size of particles in an exposure atmosphere at a concentration of 5 mg/liter. Particle size also influences deposition site in the respiratory tract. Since damage to any region of the respiratory tract can produce lethality, and it is not possible to predict, a priori, the most responsive region of the tract or the most harmful particle size of an untested agent, acute limit testing should employ particles in a size range that deposits throughout the entire rodent respiratory tract. Particles between 1 and 4 µm mass median aerodynamic diameter (MMAD) are well suited for such studies. It is, therefore, recommended that the limit test concentration should be the highest concentration (up to 5 mg/liter) that can be achieved while still maintaining a particle size distribution having an MMAD between 1 and 4 µm.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.