Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by RAMSEY, J. D.
Right arrow Articles by SCOTT, R. C.
Right arrow Search for Related Content
PubMed
Right arrow Articles by RAMSEY, J. D.
Right arrow Articles by SCOTT, R. C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1994 Oxford University Press

research-article

The Predictive Accuracy of in Vitro Measurements for the Dermal Absorption of a Lipophilic Penetrant (Fluazifop-Butyl) through Rat and Human Skin

J. D. RAMSEY1, B. H. WOOLLEN, T. R. AUTON and R. C. SCOTT

ZENECA Central Toxicology Laboratory Alderley Park, Nr Macclesfield, Cheshire, SK10 4TJ, United Kingdom

Received May 26, 1993; accepted February 21, 1994

The predictive accuracy of in vitro measurements in estimating dermal absorption has been evaluated in rat and human skin using fluazifop-butyl (FB), a lipophilic model compound, at dosage rates of 2.5, 25, and 250 µg/cm2 In vitro studies used rat and human epidermal membranes mounted in static diffusion cells with radiolabeled FB and receptor fluids of 50% aqueous ethanol (Aq Et), 6% polyethylene glycol 20 oleyl ether in saline (PEG), or tissue culture medium (TCM). In vivo rat studies with radiolabeled FB were carried out to parallel previously published human volunteer studies. For rat skin, in vitro measurements with all types of receptor fluid provide an adequate prediction (generally within a factor of 3) of in vivo absorption. Absorption data for human epidermal membranes with a receptor fluid of Aq Et were adequately predictive of the in vivo absorption. In contrast, membranes with PEG or TCM significantly underestimated the in vivo absorption. The results support the conclusion that in vitro studies are useful to predict in vivo dermal absorption in rat and man, when appropriate receptor fluids are used.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.